Can the Entrance and Exit Shielding Curtains of a Food Inspection Machine Use Different Structures? / 食品检测机入口与出口的射线防护帘能否采用不同结构?

Can the Entrance and Exit Shielding Curtains of a Food Inspection Machine Use Different Structures?

Yes. The entrance and exit curtains of a food X-ray inspection machine can use different structures. Each opening may have its own grade, strip width, overlap, or number of curtain rows. Each opening must pass its own leakage survey on the installed machine, at the operating tube voltage and beam conditions, with product moving through.

The two tunnel ends rarely face the same radiation field. Dose rate at each end depends on:

- where the X-ray source and detector sit along the tunnel - how the internal baffles are arranged - how much scatter the product directs toward that end

The ends also handle product differently. Specify each opening for its own radiation load and mechanical load.

Why Entrance and Exit Curtain Loads Differ

On the entrance side, product arrives from an infeed transfer. Items may be unevenly spaced, slightly rotated, or unstable. Light packs have to push the strips aside without stalling, tipping, or bridging. A hang-up here breaks the inspection sequence before scanning starts. Strip stiffness and contact resistance therefore tend to dominate the entrance design.

On the exit side, product has already been scanned and moves toward a reject device or downstream conveyor. Strips that drag on a pack as it leaves can disturb its position or timing at the rejector. If the source sits closer to one end of the tunnel, that end may need more attenuation or a second row.

Which end needs the heavier configuration depends on the machine layout and is confirmed by measurement.

Confirm these inputs first, as named in the manufacturer's application data:

- package size and weight - belt speed and scanning mode - grease, temperature, and cleaning conditions - contact-use documentation - installed behavior, including strip overlap and return action, assessed with whole-machine shielding measurement

Lead-Free Food Inspection Curtain Grades and Their Conditions

The Newlife - Radbar food inspection curtain catalog lists three lead-free grades. All have a light-blue polyurethane surface described as oil-resistant and easy to clean.

Grade Lead equivalence (mmPb) Listed tube voltage (kV) Areal density (kg/m²) Catalog item-weight reference
0125JBU 0.125 90 / 120 1.78 ≥80 g
0175JBU 0.175 90 / 120 2.4 ≥150 g
0250JBU 0.25 90 / 120 3.1 ≥200 g

Source: Newlife - Radbar food inspection curtain catalog, p. 2, as presented on the food inspection application page. Item weight is a selection reference and does not guarantee passage. Listed width is 600 mm / max 1200 mm; confirm supplied width. Custom range is 0.125–0.5 mmPb. Listed temperature range is −40 to 70 °C; the material is described as staying flexible at −10 °C.

Lead equivalence is stated with tube voltage, beam quality, filtration, geometry, and the applicable standard. Leakage at a tunnel end is established by a survey of that installed opening.

Structural Variables That Can Differ Between the Two Openings

Variable Entrance-side consideration Exit-side consideration What to verify
Curtain grade Lighter grade may reduce stalling of light packs Heavier grade if the measured field at this end is higher Dose rate at the opening at operating kV
Number of rows A single row may keep contact resistance low Two staggered rows can add attenuation and cover gaps Leakage while a pack holds the first row open
Strip width Narrower strips let small items pass with less force Wider strips reduce the number of seams Gap behavior at strip edges
Strip overlap Enough overlap to close after each pack Overlap that does not drag product toward the rejector Return action at production belt speed
Side clearance Fit against tunnel walls Same requirement Edge leakage at both side walls

Strip mass changes how hard each strip presses on passing product. For strips of one grade, total curtain mass is:

m=σA·w·h·n

where:

- σA is areal density - w is strip width - h is hanging height - n is the number of strips in all rows

Count every strip, including overlap and a second row, in n. A higher grade raises listed lead equivalence and strip mass. An added row raises mass and can close gaps left by the first row. Put the extra mass at the opening whose measured field requires it. The formula gives curtain mass.

Verifying Each Opening Separately

In the United States, cabinet X-ray systems are regulated under 21 CFR 1020.40. Emission shall not exceed 0.5 milliroentgen in one hour at any point 5 cm outside the external surface. Confirm the limit that applies to the destination machine.

Survey each opening as a separate acceptance item:

1. Measure with the curtains at rest. 2. Measure while the smallest and the largest production packs pass through. 3. Measure at both side walls, where the strip ends meet the tunnel.

A mixed configuration can meet the at-rest reading and still leak when a pack holds the first row open before the second row has closed. Repeat the survey after cleaning and after a run-in period. Strips that take a set, shift on their hangers, or wear at the bottom edge change the overlap.

Food-contact suitability is a document check separate from the leakage survey. Request contact-use documentation for every grade installed, under the framework that applies in the destination market, such as Regulation (EC) No 1935/2004 in the EU. If the openings use different grades, collect documentation for both.

Failure Modes Seen in Mixed Configurations

Asymmetric return is a practical failure mode. A light entrance grade can close quickly while a heavier exit curtain swings longer. At high belt speed, the exit curtain may stay partly open between closely spaced packs.

Edge leakage is a second risk. A different strip width at one end can leave a different side gap than the tunnel design assumed.

Mixed grades also complicate spares. Label spare strips by position so a cleaning crew does not refit an exit strip at the entrance. The same applies to similar-looking strips cut from different grades.

How Newlife - Radbar Supports Different Entrance and Exit Structures

Newlife - Radbar supplies food inspection curtains as rolls, OEM complete sets, or single strips. A machine builder can order different grades for each opening, or replace one end without changing the other. Catalog grades are 0.125, 0.175, and 0.25 mmPb, with custom levels from 0.125 to 0.5 mmPb.

Each grade carries its own listed voltage and areal density, so entrance and exit choices can be filed separately. The application engineering team can review tunnel geometry and pack range before the configuration is fixed. Acceptance of the installed machine rests on the opening surveys.

FAQ

Can I use a single row at the entrance and two rows at the exit? Yes, if the leakage survey at each opening passes with product moving through. Check that the second row closes before the next pack arrives at production speed.

Do the catalog item-weight references decide which grade goes at each end? Use them to start the passage check. Confirm with the lightest and least stable packs on the actual conveyor.

Can I fit a security-scanner curtain at one end of a food machine? Security curtains are listed to ≤120 kV (ProShield) or ≤160 kV (BaseShield and UltraShield), with a black VBK film or FBK fabric coating. Check cleaning compatibility and contact-use documentation before placing one on a food line.

Does a heavier exit curtain make the entrance survey unnecessary? No. Each opening is a separate emission point and needs its own measurement.

Next Steps

- Map source position and internal baffles relative to both tunnel ends. - List pack sizes, weights, belt speed, and cleaning chemistry. - Draft a configuration for each opening and estimate curtain mass from areal density, strip width, hanging height, and strip count. - Plan separate at-rest and in-motion leakage surveys for the entrance and the exit. - Contact the Newlife - Radbar application engineering team with the machine model, tube voltage, opening dimensions, target leakage limit, pack range, and cleaning requirements: https://www.newlifexray.com/en/applications/food

References

1. Newlife - Radbar. Food inspection application page and food inspection curtain catalog, p. 2 (data checked 2026-09-24). https://www.newlifexray.com/en/applications/food 2. Newlife - Radbar. Radiation Protection FAQ. https://www.newlifexray.com/en/faq 3. Newlife - Radbar. Lead-Free X-Ray Shielding Technology (source document dated 2023-08-07). https://www.newlifexray.com/en/technology/lead-free-xray-shielding 4. U.S. Code of Federal Regulations, Title 21, §1020.40, Cabinet x-ray systems. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-J/part-1020/section-1020.40 5. Regulation (EC) No 1935/2004 of the European Parliament and of the Council on materials and articles intended to come into contact with food. https://eur-lex.europa.eu/eli/reg/2004/1935/oj