RADBAR / SELECTION GUIDE

Radiation Shielding Product Selection Guide

Match the radiation source, protection format and test conditions to the right Radbar product family, from garment cores and scanner curtains to panels, clear lead acrylic and gamma materials.

SHORT ANSWER

How do you choose the right radiation shielding product?

Start with the radiation type and operating conditions, then choose the protection format: something worn, an equipment opening, a room enclosure or a local source. The Radbar catalog covers 12 product families; 9 are lead-free, while clear lead acrylic, protective eyewear and face shields contain lead. Compare lead equivalence only when radiation quality, beam geometry and test method match.

Reviewed 2026-09-24 · values from the model catalogs and editions cited

FOUR STEPS

From radiation conditions to a product family.

  1. 01

    Identify the radiation and its conditions

    X-ray equipment: tube-voltage range, filtration and duty. Gamma sources: radionuclide, spectrum, geometry and measured dose rate.

  2. 02

    Decide what must be protected

    A person (garment, collar, eyewear), an equipment opening (curtain, accessory), a room (panel, window) or a local source (flexible wrap).

  3. 03

    Compare only like-for-like data

    Lead equivalence and attenuation need the same radiation quality, beam geometry, method and tested construction before they can be compared.

  4. 04

    Prepare the inputs and request evidence

    Send the checklist below and ask for reports that match the grade, sample construction and beam conditions.

SELECTION MAP

From the radiation source to a product family.

Industrial and security X-ray equipment
Equipment tunnel openings
X-ray rooms and inspection enclosures
Walls, doors and viewing windows
X-ray equipment manufacturing (OEM)
The tube assembly inside the equipment
A specific gamma source
Local shielding at the source

SELECTION MATRIX

Find the product family for the need.

Need, product and catalog range
NeedProduct familyRadiationKey catalog rangeMaterial
Manufacturing X-ray protective garmentsMedical shielding coreMedical X-ray0.125–0.25 mmPb; 60–150 kV by series; 1.3–3.6 kg/m²Lead-free
Scatter around the interventional fieldScatter protection drapesMedical X-ray300 × 300 to 600 × 800 mm; >60% at 80 kVp (manufacturer value)Lead-free
Single-use head and neck protectionDisposable collars & capsMedical X-ray0.125–0.50 mmLE, five gradesLead-free
Mobile C-arm accessoryC-arm radiation shieldMedical X-rayRequest model dimensions and lead equivalenceLead-free
Eye protectionX-ray protective eyewearMedical X-ray0.07 mmPb; 55 gLead-containing
Eye and face protectionRadiation face shieldsMedical X-ray0.125 mmPb; 300–360 gLead-containing
Viewing windows and transparent barriersClear lead acrylicX-ray0.07–0.5 mmPb; 87–93% light transmissionLead-containing
Food and pharmaceutical inspection tunnelsFood scanner curtainsIndustrial X-ray0.125–0.25 mmPb; 90 / 120 kVLead-free
Baggage and parcel screening tunnelsSecurity X-ray curtainsSecurity X-ray0.35–1.0 mmPb listed (0.125–2.0 custom); ≤120 / ≤160 kVLead-free
Walls of imaging or inspection roomsLead-free shielding panelsX-ray2 mmPb as listed (confirm conditions); 25 / 37 kg/m²Lead-free
Shielding and insulation around X-ray tubes (OEM)Lead-free X-ray tube shielding sleevesMedical and industrial X-rayEpoxy 2.4–2.7 mmPb @ 180 kV; silicone ≥ 2.1 mmPb at 4.5 mm; AC/DC 20 kVLead-free
Local gamma shielding for maintenanceGamma shielding materialsSource-specific gammaALF: Am-241 / <100 keV, 0.125 / 0.25 mmPb (2021 catalog)Lead-free

Ranges are taken from each product catalog with their conditions. Values in different rows come from different test conditions and cannot be ranked. See each product page and original PDF for models, test conditions and supply status.

Reviewed 2026-09-24

BY APPLICATION

Open a complete application guide.

SPECIFICATION CHECKLIST

Prepare this before you ask.

  • Radiation source or equipment model
  • Operating voltage or energy spectrum, and known filtration
  • Target attenuation or lead equivalence, with test method
  • Dimensions, drawings and areal-weight limits
  • Flexibility, mounting and processing needs
  • Cleaning, temperature and duty cycle
  • Target market and required documentation
  • Expected quantity and timeline
FAQ / FREQUENTLY ASKED QUESTIONS

Questions worth asking.

What should accompany a lead-equivalence value?

Include radiation quality or tube-voltage range, measurement geometry, test method and the tested construction. Identical mmPb labels are not enough to establish equivalent performance.

What information helps Radbar select a material?

Provide the source or equipment, operating voltage or spectrum, filtration where known, target attenuation or lead equivalence, test method, dimensions, areal-weight limit, flexibility, cleaning and destination market.

Can a market voltage chart determine my specification?

No. A market chart does not describe your equipment. Use its operating envelope, source data and intended geometry, and validate the complete assembly rather than assuming one voltage covers an entire industry.

LET’S ENGINEER WHAT’S NEXT

Your application. Our next conversation.

Share your equipment, radiation conditions and design constraints. Start with a material decision grounded in evidence.