A prospective clinical investigation evaluating occupational radiation exposure during minimally invasive vascular interventions has demonstrated that interventional radiologists experience substantial differences in radiation dose rates depending on procedural type, fluoroscopy duration, and practitioner characteristics. Conducted at the General Hospital of Ningxia Medical University between April 2024 and September 2025, the study prospectively monitored 222 routine transarterial embolization cases across five clinical categories. By utilizing continuous real-time electronic dosimeters rather than traditional delayed-readout badges, researchers captured immediate intraoperative exposure data as primary operators carried out image-guided interventions. The findings revealed that genicular artery embolization produced the highest radiation dose and dose rate for primary operators alongside prolonged fluoroscopy times, whereas bronchial artery embolization yielded the lowest occupational exposures. Furthermore, nearly ten percent of enrolled patients received an estimated effective radiation dose exceeding international safety thresholds, underscoring the necessity of systematic real-time dosimetry in modern catheter-based practice.
Interventional radiology represents one of the fastest-growing disciplines in modern healthcare, establishing itself as a foundational therapeutic approach alongside internal medicine and open surgical intervention. However, extensive reliance on continuous fluoroscopic X-ray visualization exposes both patients and clinical staff to ionizing radiation. Such intraoperative occupational exposure carries deterministic biological risks, including cutaneous injury, alongside long-term stochastic hazards, most notably radiation-induced cancer. Historically, clinical facilities have quantified staff radiation burdens using passive thermoluminescent dosimeters requiring laboratory processing over intervals spanning several months. This reporting latency impedes immediate procedural feedback, leaves cumulative exposure unaddressed in real time, and imposes heavy administrative workloads. While real-time active dosimeters have gained acceptance across cardiac catheterization suites, neurosurgical operations, and orthopedic procedures, peripheral vascular interventions have lacked comprehensive, comparative intraoperative dosimetric evaluation. To address this evidence gap, the investigators sought to track dynamic personal dose equivalents during peripheral procedures, identifying modifiable and structural factors that dictate occupational exposure under standardized angiographic conditions.
The prospective clinical cohort enrolled adult patients aged between 24 and 90 years who underwent therapeutic transarterial embolization at the study institution. From an initial enrollment of 230 candidate procedures, eight cases were excluded during preliminary screening because operators departed from designated procedural stations, dosimetric records were incomplete, or multiple simultaneous interventional procedures were performed across distinct anatomical sites within a single session. The remaining 222 successfully monitored procedures were categorized into five therapeutic cohorts: 133 transarterial chemoembolization procedures primarily targeting hepatocellular carcinoma, 35 bronchial artery embolizations, 26 renal artery embolizations, 15 uterine artery embolizations, and 13 genicular artery embolizations. Baseline patient evaluations systematically captured demographic variables including age, sex, and body mass index, while procedural documentation logged primary operator height, years of formal clinical experience in interventional practice, total fluoroscopy time, cumulative kerma-area product, and cumulative air kerma, establishing a comprehensive dataset for multivariable statistical evaluation.
All 222 vascular procedures were performed inside a single dedicated interventional suite utilizing a floor-fixed Siemens Axiom Artis DTA digital subtraction angiography system equipped with an under-table X-ray tube. Fluoroscopic imaging operated in pulsed mode at 15 pulses per second filtered through 0.6 millimeters of copper and 1.0 millimeter of aluminum, while digital subtraction angiography runs were acquired at 4 frames per second with 0.1 millimeters of copper and 1.0 millimeter of aluminum filtration. Intraoperative imaging alternated between standardized visual fields, predominantly employing a small 10 by 10 centimeter field of view or a large 20 by 30 centimeter configuration. The procedural team adhered to uniform radiation protection measures, combining collective shielding—consisting of a 75 by 75 centimeter lead screen and an 80 by 115 centimeter under-table lead curtain—with individual personal protective equipment, including lead aprons, thyroid shields, and protective goggles. Real-time occupational dosimetry was recorded continuously using Ecotest VIP personal dosimeters based on Geiger-Müller counter detection, calibrated from 0.1 microsieverts to 9.9 millisieverts.
The personal dosimeter was stably affixed to the outer surface of the primary operator’s protective lead apron at the left upper chest to monitor the personal dose equivalent at a standardized tissue depth of 10 millimeters, designated as Hp(10). External positioning was chosen because the dosimeter cannot reliably detect low-dose radiation penetrating lead shielding, providing an established surrogate metric for relative upper-body exposure across comparative cohorts. The primary outcome metric was the radiation dose rate, defined as total accumulated dose divided by procedural duration in hours. Patient radiation burdens were quantified through total kerma-area product and estimated effective dose values derived using procedure-specific conversion coefficients: 0.15 for chemoembolization, 0.12 for bronchial interventions, 0.26 for renal embolization, 0.29 for uterine embolization, and 0.01 for genicular interventions. Given non-normal data distributions, researchers evaluated continuous variables using non-parametric Mann-Whitney U tests and Kruskal-Wallis H tests, subsequently developing multivariable linear regression models with stepwise backward elimination to isolate independent determinants of operator exposure.
Comparative analyses revealed stark, statistically significant disparities in radiation exposure metrics across the five embolization categories. Genicular artery embolization incurred the highest radiation burden for primary operators, with median individual exposure reaching 49.00 microsieverts and a median dose rate of 129.89 microsieverts per hour, coupled with the longest median fluoroscopy time of 24.00 minutes. Conversely, uterine artery embolization generated the highest overall patient radiation burden, exhibiting a median fluoroscopy kerma-area product of 106.52 gray-square-centimeters, a median fluoroscopy air kerma of 335.10 milligrays, and a median patient effective dose of 145.36 millisieverts. Bronchial artery embolization registered the lowest occupational radiation exposure, recording a median primary operator dose of 10.00 microsieverts and a median dose rate of 42.85 microsieverts per hour. Across all five procedural groups, primary operators sustained markedly higher radiation exposures than secondary assisting operators, directly confirming the physical inverse-square law governing spatial distance from the primary scatter source.
A critical finding was that 19 patients, representing 9.79 percent of the cohort, received an estimated effective radiation dose exceeding 100 millisieverts, a recognized threshold established in Publication 103 of the International Commission on Radiological Protection beyond which the risk of stochastic oncogenic effects increases. These high patient doses were predominantly concentrated among complex abdominal interventions, particularly uterine and chemoembolization cases. Bivariate correlation analyses demonstrated that the primary operator’s radiation dose correlated positively with total fluoroscopy time and fluoroscopy kerma-area product, accounting for coefficients of determination of 0.147 and 0.43, respectively. The pronounced operator exposure recorded during genicular artery embolization was attributed to its status as an emerging, technically challenging procedure characterized by intricate vascular anatomy, delicate collateral branches, and sharp angular vessel trajectories that demand repetitive fluoroscopic verification. Conversely, bronchial interventions involved lower thoracic tissue densities that allowed the imaging system to operate at lower tube voltages and currents, minimizing overall secondary scatter.
Multivariable linear regression analysis confirmed that the primary operator’s occupational dose rate was independently governed by patient, operator, and technical variables. Elevated patient body mass index of 25 kilograms per square meter or greater significantly increased scatter generation, yielding an independent regression coefficient of 30.863. Crucially, operator physical stature exhibited an inverse relationship with radiation burden; operators taller than 175 centimeters experienced significantly lower dose rates than shorter colleagues, reflected by a regression coefficient of negative 18.704. In an under-table tube configuration, secondary scatter originates primarily from the patient’s irradiated body; taller operators maintain a greater vertical distance between their upper chest and the primary scattering zone, attenuating the scatter reaching their torso. The utilization of a small 10 by 10 centimeter visual field significantly lowered exposure rates, yielding a coefficient of negative 21.977 compared to larger imaging fields.
To disentangle the interplay between operator height and clinical experience, researchers conducted subgroup evaluations within a homogenous cohort of 87 chemoembolization patients treated exclusively under small visual fields. In the first subgroup, comprising operators with less than five years of experience, patient body mass index did not differ significantly between stature groups, yet shorter operators sustained significantly higher dose rates than taller operators, with median rates of 98.04 versus 78.06 microsieverts per hour. In the second subgroup of senior operators with over five years of experience, patient body mass index was similarly comparable, but shorter operators again sustained significantly elevated dose rates of 123.53 versus 67.31 microsieverts per hour. Further linear model testing confirmed that the differential impact of operator height remained statistically significant after adjusting for clinical experience, and experience remained significant after controlling for stature.
Despite its prospective design and granular dosimetric tracking, the authors emphasized several methodological limitations that warrant prudent interpretation. First, case distribution across embolization categories was uneven, with the genicular cohort restricted to 13 patients, prompting caution regarding cross-procedural generalizations. Second, several intraprocedural determinants—such as specific C-arm projection angles, real-time shielding adjustments, table elevation changes, contrast injection protocols, fluoroscopic pulse adjustments, and operator handedness—were not systematically recorded and could not be incorporated into regression modeling. Consequently, identified associations represent statistical correlations rather than direct causal mechanisms. Third, the study cohort included exclusively male operators, precluding gender-stratified analyses regarding physical stature and protective behavior. Finally, as a single-center trial utilizing a single angiographic system, operational protocols may not generalize to centers employing overhead tubes or alternative shielding arrays. The authors recommend that centers establish automated electronic dose tracking, flag patients receiving over 100 millisieverts for clinical follow-up, and tailor physical radiation protection strategies to individual operator geometry.